Remote Telemetry Units

A723 addIT Series 4 A723 addIT Series 4
A compact 10mW RTU with integrated SDI-12 capability, lots of I/O ports, lots of memory, and more at a very attractive price
A724 addSWITCH Series 4 A724 addSWITCH Series 4 Valve Controller
Turns latching solenoids on and off, reads meters, monitors pressure
A731 addRELAY UHF Relay A731 addRELAY UHF Relay
A731 extends the operating radius of other Adcon RTU's and economically optimizes radio quality
A733 addWAVE UHF A733 addWAVE UHF
The A733 addWAVE is the "work horse " in the Adcon range of RTU's, ideally suited for transmitting lots of sensor data over large distances
A753 addWAVE GPRS RTU A753 addWAVE GPRS RTU
A753 GPRS is a multi-purpose, universal data logger – excellent resolution, lots of memory, WMO compliant, and much more
A755 GSM/GPRS SDI-12 A755 GSM/GPRS SDI-12
Economically stores and transmits data from all environmental sensors with SDI-12 interface
A757 addPULSE GPRS A757 addPULSE GPRS
Custom-RTU to read pulse counters, be they rain gauges or water meters. Perfect for rain intensity monitoring
RA440 - Remote A440 RA440 - Remote A440
For all those remote areas where you don't have GSM coverage, and where you can't put a Base Station near your UHF RTU's
Dimensions 100 x 70 x 40 mm
Weight 450g
Protection type IP-67
Transmission distance up to 1.000 m (dep. on topography)
Power Supply internal 6.2V NiMH battery w. 2200 mAh, charged by solar panel or mains adapter
6 Analog inputs 0 - 2.5 V with 12-Bit resolution or
0 - 1V with 11-Bit resolution
2 Counter Inputs for standard reed switches as used eg. in rain gauges or water meters. Max. frequency 30 pulses per second; min. pulse length 17ms, min. break time 17ms
SDI-12 port: On-Board via I/O port A. Accepts up to 40 sensor values
2 Digital I/O's Configurable as either TTL-inputs for status control or as TTL-outputs to switch a relay (might require relay amplifier interface ADI-24)
Stabilized Sensor Excitation Adjustable from 3.3V to 5.5V
Unregulated Sensor
Excitation
Feeds battery voltage to the sensors, unregulated from 5.6V to 7.5V
Memory 64KB for up to 20.000 readings (dep. on type of sensors attached)
Connectors 2 x Binder M9 7-pin female (Sensor)
1 x Binder M9 5-pin female (Power)
Mounting Mast mounting bracket
Temperature range -30°C... +70°C
Radio:
Tx Output Power 10mW
Rx Sensitivity -110dBm
Frequency range 432 ... 470MHz
Type Approvals R&TTE, CE, FCC, Ind.Canada, AUS
Dimensions 119 x 79x 60 mm  /  4,7 x 3,1 x 2,4 inch
Weight 680g   /  1,5 lb
Protection Type IP-67
Transmission Distance max. 1.000 m /  3.000 ft., depending on topography
Power Supply Internal 6.2V NiMH battery, 2.1Ah, charged by solar panel or mains adaptor
4 Valve outputs To operate latching solenoids with DC voltages from 5.5V to 15VDC
4 Counter inputs: For standard reed switches as used e.g. in rain gauges or water meters with up to 30 pulses per second; min. pulse length 17ms, min. break time 17ms
1 Analog input
To connect one single ended analog sensor, 0-2.5V output signal; output provides sensor excitation with battery voltage
Memory 16KB for up to 10.000 values
Connectors 1 x Switchcraft 6-pin female to solenoids
1 x Binder M9 7-pin female to pulse counters and analog port
1 x Binder M9 5-pin female to solar panel / power source
Accessories supplied 1 x 50cm cable Switchcraft connector for 4 solenoids
1 x 32-50mm cable clamp to mount RTU to pole
Mounting Mast mounting bracket, ideal for 40mm pole sets
Operating temperature -30°C ... +70°C   /   -22°F ... +158°F
Tx Output Power 10mW
Rx Sensitivity -110dBm
Operating frequency 432 - 470MHz
Approvals R&TTE, CE, FCC, Ind.Canada, ACMA Australia
Dimensions 160 x 60 x 80 mm
(6.3 x 2.4 x 3.1 inch)
Weight 1210g (2.5 lb)
Protection Type IP-67
Transmission Distance max. 20km (12 miles)
(depending on topography)
Power Supply internal 6.2V NiCd battery, charged by solar panel or mains adaptor
Connector 1 x Binder M9 5-pin female for solar panel or mains adaptor
Mounting Mast mounting bracket
Operating temperature -30°C - +60°C (-22°F - +140°F)
Tx Output Power 500mW
Rx Sensitivity -120dBm (10 dB S/N)
Operating frequency 430 - 470MHz
Channel Spacing 12.5 / 25kHz (factory set)
Approvals R&TTE, CE, FCC, Ind.Canada, AUS
Dimensions 160 x 60 x 80 mm (6.3 x 2.4 x 3.1 inch)
Weight 1250g (2.5 lb)
Protection type IP-67
Transmission Distance max. 20km (max. 12 miles)
(depending on topography)
Power Supply internal 6.2V NiMH battery, charged by solar panel or mains adaptor
12 Analog Inputs 0 ... 2.5 V with 10-bit resolution
4 Counter Inputs for standard reed switches as used e.g. in rain gauges or water meters. 2 pulses per second in debounce mode, 30 pulses per second in fast count mode
SDI-12 Bus Optional via external A506 SDI-12 Adaptor. Accepts up to 20 sensor values.
4 Digital In-/ outputs Configurable as either TTL-inputs for status control or as TTL-outputs to switch a relay (might require relay amplifier interface ADI-124)
Memory 32KB for up to 20.000 readings (depending on types of sensors attached)
Connectors 4 x Binder M9 female 7-pin
1 x Binder M9 female 5-pin
Mounting Mast mounting bracket
Operating temperature -30°C ... +65°C
Tx Output Power: 500mW
Rx Sensitivity -120dBm (10 dB S/N)
Frequency range 430 ... 470MHz
(please specify your 10MHz band when ordering)
Channel Spacing 10 / 12.5 / 25 kHz (factory preset)
Approvals R&TTE, CE, FCC, Ind.Canada, ACMA Australia
Technical Specifications - Mechanics
Case Aluminum, powder coated
Protection class
IP-67
Dimensions and weight 160 x 60 x 80 mm / 6.3 x 2.4 x 3.1 inches
1.150g/ 2.4lb.
Connectors for sensors and power Made in Germany by Binder
IP-67 protection class
Sockets: brass, nickel plated
Socket contacts: gold plated
Protective cap
4 x M9 female 7-pin to sensor
1 x M9 female 5-pin to power
Antenna connector TNC with external seal, water tight, Made in Germany
Mounting Mast mounting bracket integrated
Operating temperature -20°C...+65°C/-4°F...149°F
-30°C...+75°C/-22°F...167°F extended temperature range upon
request
Technical Specificatios - Logger
Total number of channels 60
Analog inputs 12 x 0 - 1V resp. 0 - 2.5V DC   ( 3 of which can also be set to a range of 0 - 150mV DC low  temp. drift)
Digital inputs 40 x SDI-12 values
Counter inputs 4, with the following configuration:
I/O A + I/O D: for standard Reed switches; electronically
debounced, e.g. for rain gauges; up to 30Hz; min. pulse length 17ms, min. break time 17ms
I/O B + I/O C: for fast pulse counting (electronically generated pulses), e.g. for wind speed sensors or flow meters; up to 500Hz; min. pulse length 1ms, min. break time 1ms 
TTL Inputs/Outputs 4 x TTL compatible status inputs or switching outputs,
configurable; 
2 x 5V and 2 x 3.3V
Analog resolution 16-Bit
Sensor Excitation Prgrammable:
- Unregulated battery voltage from 5.5V - 7.5V
- Regulated voltage, programmable from 3.3V - 5.5V
Memory
2MB for up to 500.000 readings; dynamic memory assigment, depending on the types of sensors used;
Example: 15-minute values of a standard weather station for 6 month
Special Logger Functionality
Wind Gust Monitoring Port C + Adcon Wind sensor:  4 samples per second; averaging over the last 12 samples every 250ms; stores date and time of the highest wind gust
Wind Vector Monitoring Port C + Adcon Wind sensor: Direction is sampled at the same time as speed, weighed according to speed and stored as vector
Rain Intensity Port D + Rain Gauge with pulse output (max. resolution: 1 Hz)
Date and time of each pulse are stored; up to three additional
analog signals can be stored at the same time, e.g. wind speed
and temperature
Pressure Hammer
Monitoring
Port C + Adcon Manometer sensor: the sensor is supplied permanently, samples 4 x per second and calculates 3-second averages
Low Voltage Amplifier Port B: accepts sensors with output signals from 0 ... 150mV
Sequential sampling To avoid interference between sensors the four ports A to D can also be sampled sequentially
Event Monitor To detect status changes on digital inputs each such input can be sampled once per second; date and time of each status change
will be stored. Application: error detection of equipment, access control, pump monitoring, etc.
Technical Specifications - Data transmission
Frequencies 900 & 1800 MHz (Europe) and
850 & 1900 MHz (Americas)
Modem Motorola G24L
SIM-Cards small footprint
Security SIM-Cards are PIN-Code protected!
Connection types - GSM: CSD Circuit Switched Data
- GPRS
GPRS Connect Frequency User selectable:
- permanent connection 
- connect from 1 x per minute to 1 x per day
Antenna Omnidirectional, +2dBi, TNC, waterproof
Technical Specifications - General
Power supply internal 6.2V battery, charged by solar panel or mains adaptor;
optional: non-rechargeable Lithium-Thionyl battery (to operate the RTU w/o solar panel)
Battery Panasonic High-temperature-Industrial Grade NiMH battery,
3100mAh
Type approvals FCC, R&TTE, CE, Industry Canada, ACMA Australia
Technical Specifications - Mechanics
Case Aluminum, powder coated
Protection class IP-67
Dimensions and weight 160 x 60 x 80 mm / 6.3 x 2.4 x 3.1 inches
1150g / 2.4lb.
Connectors for sensors and power Made in Germany by Binder
IP-67 protection class
Sockets: brass, nickel plated
Socket contacts: gold plated
Protective cap
1 x M9 female 7-pin to sensor
1 x M9 female 5-pin to power
Antenna connector
TNC with external seal, water tight , Made in Germany
Mounting Mast mounting bracket integrated
Operating temperature -20°C ... +65°C / -4°F ... 149°F
-30°C ... +75°C / -22°F ... 167°F extended temp. range upon request
Technical Specifications - Logger
Sensor Input 1 for standard SDI-12 sensors; up to 40 values can be addressed
Counter Input 1 for standard reed contacts; electronically debounced, e.g. for rain gauges; max frequency up to 30 pulses per second; min. pulse length 17ms, min. break time 17ms
Memory 2MB for up to 250.000 readings
Technical Specifications - Data transmission
Frequencies 900 & 1800 MHz (Europe) and
850 & 1900 MHz (Americas)
Modem Motorola G24L
SIM-Cards small footprint
Security SIM-Cards are PIN-Code protected
Connection types
- GSM: CSD Circuit Switched Data
- GPRS
GPRS Connect Frequency User selectable:
- permanent connection
- connect from 1 x per minute to 1 x per day
Antenna Omnidirectional, +2dBi, TNC, waterproof
Technical Specifications - General
Power supply
internal 6.2V battery, charged by solar panel or mains adaptor;
optional: non-rechargeable Lithium-Thionyl battery (to operate the RTU w/o solar panel)
Battery Panasonic High-Temperature Industrial Grade NiMH battery, 3100mAh
Type approvals FCC, R&TTE, CE, Industry Canada, ACMA Australia
Technical Specifications - Mechanics
Case Aluminum, powder coated
Protection class
IP-67
Dimensions and weight 160 x 60 x 80 mm / 6.3 x 2.4 x 3.1 inches
1150g / 2.4lb.
Connectors for sensors and power Made in Germany by Binder
IP-67 protection class
Sockets: brass, nickel plated
Socket contacts: gold plated
Protective cap
1 x M9 female 7-pin to sensor
1 x M9 female 5-pin to power
Antenna connector
TNC with external seal, water tight , Made in Germany
Mounting Mast mounting bracket integrated
Operating temperature -20°C ... +65°C / -4°F ... +149°F
-30°C ... +75°C / -22°F ... +167°C extended temp. range upon request
Technical Specifications - Logger
Counter Inputs 1 for standard reed contacts; electronically debounced, e.g. for rain gauges; max frequency up to 30 pulses per second; min. pulse length 17ms, min. break time 17ms
Rain Intensity Monitoring Date and Time of every single pulse are stored; max. resolution: 1 second
Memory 2MB for up to 500.000 readings, depending on the programmed operating mode (totalizer or time stamping)
Technical Specifications - Data transmission
Frequencies 900 & 1800 MHz (Europe) and
850 & 1900 MHz (Americas)
Modem Motorola G24L
SIM-Cards small footprint
Security SIM-Cards are PIN-Code protected
Connection types - GSM: CSD Circuit Switched Data
- GPRS
GPRS Connect Frequency User selectable:
- permanent connection
- connect from 1 x per minute to 1 x per day
Antenna Omnidirectional, TNC, +2dBi, waterproof
Technical Specifications - General
Power supply
internal 6.2V battery, charged by solar panel or mains adaptor
Battery Panasonic High-Temperature Industrial Grade NiMH battery, 3100mAh
Type approvals FCC, R&TTE, CE, Industry Canada, ACMA Australia
Technical Specifications - Mechanics
Case Aluminum, powder coated
Protection type IP-67
Dimensions
& weight
227 x 168 x 117 mm (8.9 x 6.6 x 4.6 inch)
2900g (6.4 lbs) - case only
3308g (7.3 lbs) - case including antennas
Connector to Solar Panel Made in Germany by Binder
IP-67 protection class
1 x M9 female 5-pin with dust cap
Connector to DC Power Source Made in France by Souriau
IP-67 protection class
1 x UTS HiSeal Bayonet male 2-pin. with 2-pin
Antenna connector 2 x TNC with external seal, water tight , Made in Germany
Mounting 2 x Mast mounting brackets
Operating temperature -20°C - +75°C
Technical Specifications - Data Transmission - GSM
Frequency range 900 & 1800 MHz (Europe) and
850 & 1900 MHz (Americas)
Modem Motorola G24L
SIM Card small footprint
Security SIM cards are PIN code protected
Connection type GPRS
Antenna Omni directional quad band
Technical Specifications - Data Transmission - UHF
Tx Output Power: 500mW
Rx Sensitivity -120dBm (10 dB S/N)
Frequency range 430 - 470MHz (in bands of 10MHz)
Channel Spacing 12.5 / 25 kHz (factory preset)
Antenna Omni directional, rigid, 3dB gain, incl. mast mounting bracket and 6m of cable
Technical Specifications - General
Max. number of radio RTU's supported 15 - 20; depends on various factors: number of sensors per station, slot time and polling time
Power Supply 1 or 2 internal 6.2V batteries, charged by solar panel
Optional: external 12V DC power source, e.g. car battery
Internal Battery Panasonic High-Temperature Industrial Grade NiMH battery, 3100mAh
Approvals FCC, R&TTE, CE, Industry Canada, Radio Australia